<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>journal of research in dental sciences</title>
<title_fa>مجله تحقیق در علوم دندانپزشکی</title_fa>
<short_title>J Res Dent Sci</short_title>
<subject>Medical Sciences</subject>
<web_url>http://jrds.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>2008-4676</journal_id_issn>
<journal_id_issn_online>2228-7353</journal_id_issn_online>
<journal_id_pii>8</journal_id_pii>
<journal_id_doi>10.66224/jrds</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>14</journal_id_sid>
<journal_id_nlai></journal_id_nlai>
<journal_id_science>13</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1395</year>
	<month>10</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2017</year>
	<month>1</month>
	<day>1</day>
</pubdate>
<volume>13</volume>
<number>4</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>بررسی تاثیر ضخامت های مختلف ماده بر میزان پلیمریزاسیون در کامپوزیت های بالک فیل فلوابل</title_fa>
	<title>The Evaluation of the Effect of Different Thicknesses on Polymerization of Bulk Fill Flowable Composites</title>
	<subject_fa>ترمیمی</subject_fa>
	<subject>restorative dentistry</subject>
	<content_type_fa>مطالعه  اصیل</content_type_fa>
	<content_type>original article</content_type>
	<abstract_fa>&lt;p dir=&quot;RTL&quot; style=&quot;font-style: normal;&quot;&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp; خلاصه:&lt;/p&gt;

&lt;p dir=&quot;RTL&quot; style=&quot;font-style: normal;&quot;&gt;&lt;strong&gt;سابقه و هدف:&lt;/strong&gt; محدودیت عمق کیور و تاثیر آن بر میزان پلیمریزاسیون از مشکلات کار با کامپوزیتهای نوری می&amp;shy;باشد که عامل مهمی در شکست کلینیکی ترمیم&amp;shy;های کامپوزیتی است. یکی از راههای مقابله با آن استفاده از کامپوزیتهای بالک فیل معرفی شده اما تحقیقات تا کنون به نتیجه هماهنگی دست نیافته&amp;shy;اند لذا در این تحقیق به بررسی تاثیر ضخامت بر میزان پلیمریزاسیون سه نوع کامپوزیت بالک فیل و هیبرید در سال 1395 پرداختیم.&lt;/p&gt;

&lt;p dir=&quot;RTL&quot; style=&quot;font-style: normal;&quot;&gt;&lt;strong&gt;مواد و روش ها:&lt;/strong&gt; در این تحقیق تجربی- آزمایشگاهی دو نوع کامپوزیت بالک فیل فلوابل &lt;span dir=&quot;LTR&quot;&gt;Filtek&amp;trade; Bulk Fill Flowable &lt;/span&gt;،&lt;br&gt;
&lt;span dir=&quot;LTR&quot;&gt;X-tra&lt;/span&gt; &lt;span dir=&quot;LTR&quot;&gt;Base&lt;/span&gt; و گروه شاهد کامپوزیت هیبرید &lt;span dir=&quot;LTR&quot;&gt;Filtek&amp;trade; Z250 Universal&lt;/span&gt; را در تعداد 108 نمونه در مولدهای برنجی دارای حفره ای به ابعاد 10&amp;times;4&amp;times;2 میلی متر قرار دادیم، پس از 20 ثانیه نوردهی با دستگاه لایت کیور &lt;span dir=&quot;LTR&quot;&gt;Demi&amp;trade; Plus&lt;/span&gt; کالیبره شده با دستگاه رادیومتر &lt;span dir=&quot;LTR&quot;&gt;Minamel &lt;/span&gt;، 24 ساعت در دستگاه انکوباتور در دمای 37 درجه سانتی گراد نگهداری، سپس ریزسختی آنها در دستگاه سختی سنج &lt;span dir=&quot;LTR&quot;&gt;Vickers V-TestII&lt;/span&gt; به مدت 15 ثانیه تحت نیروی 300 گرم، 3 بار در هر یک از ضخامتهای 5-4-3-2-1-1/0 میلی متر اندازه گیری و میانگین محاسبه شد. یافته ها با آزمون آماری &lt;span dir=&quot;LTR&quot;&gt;ANOVA&lt;/span&gt; بررسی شدند.&lt;/p&gt;

&lt;p dir=&quot;RTL&quot; style=&quot;font-style: normal;&quot;&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp; یافته ها: بیشترین&amp;nbsp; ریزسختی مربوط به &lt;span dir=&quot;LTR&quot;&gt;Filtek&amp;trade; Z250 Universa&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;l&lt;/span&gt; در ضخامت 1/0 میلی متر به میزان 8/0&amp;plusmn;8/98 و کمترین آن مربوط به &lt;span dir=&quot;LTR&quot;&gt;Filtek&amp;trade; Bulk Fill Flowable&lt;/span&gt; در ضخامت 5 میلی متر به میزان 7/0&amp;plusmn;5/31 بود که این اختلاف در تمام ضخامتها به لحاظ آماری معنی دار بود. &lt;span dir=&quot;LTR&quot;&gt;)&lt;/span&gt;001/0&gt;&lt;span dir=&quot;LTR&quot;&gt;P&lt;/span&gt;)&lt;/p&gt;

&lt;p dir=&quot;RTL&quot; style=&quot;font-style: normal;&quot;&gt;&amp;nbsp; نتیجه گیری:&amp;nbsp;&amp;nbsp; به نظر می رسد ریزسختی کامپوزیت &lt;span dir=&quot;LTR&quot;&gt;Filtek&amp;trade; Z250 Universal&lt;/span&gt; در سطح ترمیم بهتر از سایر کامپوزیت هاست.&lt;/p&gt;
</abstract_fa>
	<abstract>&lt;p align=&quot;right&quot; dir=&quot;RTL&quot; style=&quot;margin: 0cm 0cm 8pt; text-align: left; line-height: normal; unicode-bidi: embed; direction: rtl;&quot;&gt;&lt;b&gt;&lt;span b=&quot;&quot; dir=&quot;LTR&quot; style=&quot;font-size: 12pt;&quot;&gt;&lt;font color=&quot;#000000&quot; face=&quot;Calibri&quot;&gt;Abstract:&lt;/font&gt;&lt;/span&gt;&lt;/b&gt;&lt;/p&gt;

&lt;p style=&quot;margin: 0cm 0cm 8pt; line-height: normal;&quot;&gt;&lt;font color=&quot;#000000&quot;&gt;&lt;font face=&quot;Calibri&quot;&gt;&lt;b&gt;&lt;span b=&quot;&quot; style=&quot;font-size: 12pt;&quot;&gt;Introduction: &lt;/span&gt;&lt;/b&gt;&lt;span b=&quot;&quot; style=&quot;font-size: 12pt;&quot;&gt;The limitation of the curing depth is one of the problems occurring while working with light curing composites which leads to clinical failure of restorations. Using the bulk fill flowable composites have been introduced as a solution to this problem, yet the researches have not had consonant results; That is why, we decided to evaluate the effect of different thicknesses on polymerization of three types of bulk fill and hybrid composites.&lt;/span&gt;&lt;/font&gt;&lt;/font&gt;&lt;/p&gt;

&lt;p style=&quot;margin: 0cm 0cm 8pt; line-height: normal;&quot;&gt;&lt;font color=&quot;#000000&quot;&gt;&lt;font face=&quot;Calibri&quot;&gt;&lt;b&gt;&lt;span b=&quot;&quot; style=&quot;font-size: 12pt;&quot;&gt;Method and Material: &lt;/span&gt;&lt;/b&gt;&lt;span b=&quot;&quot; style=&quot;font-size: 12pt;&quot;&gt;In this In-Vitro study, we put 108 specimens of two types of bulk fill flowable composites, Filtek&amp;trade; Bulk Fill Flowable(FBF) and X-tra Base(XB), and a hybrid composite, Filtek&amp;trade; Z250 Universal(Z250) as control samples, in brazen molds with 2.4.10 mm dimensions. After light curing for 20 seconds by Demi&amp;trade; Plus light cure device, calibrated by the Minamel radiometer device, we put the specimens in CO2 Incubator at 37&amp;deg;C for 24 hours, then we measured the Vickers microhardness of specimens by Vickers V-Test ll machine under 300 grams force for 15 seconds. The measurements were done three times respectively at the depths of 0.1-1-2-3-4-5 and the averages were calculated. The results were then analyzed using the ANOVA statistical testing.&lt;/span&gt;&lt;/font&gt;&lt;/font&gt;&lt;/p&gt;

&lt;p style=&quot;margin: 0cm 0cm 8pt; line-height: normal;&quot;&gt;&lt;font color=&quot;#000000&quot;&gt;&lt;font face=&quot;Calibri&quot;&gt;&lt;b&gt;&lt;span b=&quot;&quot; style=&quot;font-size: 12pt;&quot;&gt;Results: &lt;/span&gt;&lt;/b&gt;&lt;span b=&quot;&quot; style=&quot;font-size: 12pt;&quot;&gt;The highest microhardness was shown by Filtek&amp;trade; Z250 Universal at the depth of 0.1 mm (98.8&amp;plusmn;0.8) and the lowest microhardness was shown by Filtek&amp;trade; Bulk Fill Flowable(FBF) at the depth of 5 mm (31.5&amp;plusmn;0.7). The detected differences at all of the six depths were statistically significant(p&lt;0.001).&lt;/span&gt;&lt;/font&gt;&lt;/font&gt;&lt;/p&gt;

&lt;p style=&quot;margin: 0cm 0cm 8pt; line-height: normal;&quot;&gt;&lt;font face=&quot;Calibri&quot;&gt;&lt;font color=&quot;#000000&quot;&gt;&lt;b&gt;&lt;span b=&quot;&quot; style=&quot;font-size: 12pt;&quot;&gt;Conclusion: &lt;/span&gt;&lt;/b&gt;&lt;span b=&quot;&quot; style=&quot;font-size: 12pt;&quot;&gt;It seems that the microhardness of&lt;/span&gt;&lt;/font&gt;&lt;font color=&quot;#000000&quot; size=&quot;3&quot;&gt; &lt;/font&gt;&lt;span b=&quot;&quot; style=&quot;font-size: 12pt;&quot;&gt;&lt;font color=&quot;#000000&quot;&gt;Filtek&amp;trade; Z250 at the surface of restoration is better than that of the two other composites.&lt;/font&gt;&lt;/span&gt;&lt;/font&gt;&lt;/p&gt;
</abstract>
	<keyword_fa>کامپوزیت رزین, ریزسختی, پلی مریزاسیون,Filtek z250, Filtek  Flow</keyword_fa>
	<keyword>Bulk Fill Flowable Composites, Microhardness,Filtek Z250, Filtek Flow</keyword>
	<start_page>167</start_page>
	<end_page>173</end_page>
	<web_url>http://jrds.ir/browse.php?a_code=A-10-1152-1&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>K</first_name>
	<middle_name></middle_name>
	<last_name>Saati</last_name>
	<suffix></suffix>
	<first_name_fa>کیوان</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>ساعتی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>100319475328460010839</code>
	<orcid>100319475328460010839</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>دانشگاه آزاد اسلامی واحد دندانپزشکی</affiliation_fa>
	 </author>


	<author>
	<first_name>H</first_name>
	<middle_name></middle_name>
	<last_name>Heshmat</last_name>
	<suffix></suffix>
	<first_name_fa>هاله</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>حشمت</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>100319475328460010840</code>
	<orcid>100319475328460010840</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>دانشگاه آزاد اسلامی واحد دندانپزشکی</affiliation_fa>
	 </author>


	<author>
	<first_name>N</first_name>
	<middle_name></middle_name>
	<last_name>valaei</last_name>
	<suffix></suffix>
	<first_name_fa>ناصر</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>ولایی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>100319475328460010841</code>
	<orcid>100319475328460010841</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>دانشگاه آزاد اسلامی واحد دندانپزشکی</affiliation_fa>
	 </author>


	<author>
	<first_name>T</first_name>
	<middle_name></middle_name>
	<last_name>Lessan</last_name>
	<suffix></suffix>
	<first_name_fa>طوبی</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>لسان</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>toubalessan@ymail.com</email>
	<code>100319475328460010842</code>
	<orcid>100319475328460010842</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>دانشگاه آزاد اسلامی واحد دندانپزشکی</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
