[Home ] [Archive]   [ فارسی ]  
:: Main :: About :: Current Issue :: Archive :: Search :: Submit :: Contact ::
Main Menu
Home::
Journal Information::
Articles archive::
For Authors::
For Reviewers::
Registration::
Contact us::
Site Facilities::
Indexing & Abstracting::
::
(CC-BY 4.0)

AWT IMAGE

Journal of Research in Dental Sciences is licensed under a "Creative Commons Attribution 4.0 International (CC-BY 4.0)"

..
Search in website

Advanced Search
..
Receive site information
Enter your Email in the following box to receive the site news and information.
..
:: Volume 13, Issue 1 (JRDS 2016) ::
J Res Dent Sci 2016, 13(1): 8-13 Back to browse issues page
Protective Effect of thyroid shield (AKTIF EP 316) on the absorbed dose of thyroid gland in panoramic radiography
L Hafezi , T Mohammad Nejad , S Vejdannik *
Post Graduate Student of maxillofacial Radiology department, Dental branch, Islamic Azad University, Tehran. Iran , 30ma.gemini@gmail.com
Abstract:   (10824 Views)

Background and aim:   protecting   the  thyroid   gland   during panoramic radiography with shielding is not recommended. in this study ,the effect of  using  thyroid  protecting  shield  ( AKTIF EP 316 )  on thyroid dose of patients  visiting  a  private clinic in Tehran in 1392-93 was investigated

Materials and methods:  In  this  clinical  trial  study  20 men  with similar height, weight and age were  selected among patients whom prescribed panoramic radiography. The dosimeters ( TLDs) were placed on  the  front and back side of shield and radiography was performed with  similar conditions (MA=10 , KVP=72-76 , 18 s time) using a CRANEX D  machine and done for every 10 patients with similar series of dosimeters. Then the  TLDs  were read and data's were evaluated by Fischer exact test and T- test.

Results: All the  images were  assessed with the Fischer test , were acceptable and the thyroid protecting shield did not  prevent the visualization of the anterior teeth. The absorbed dose of thyroid gland when the dosimeters mounted on the front side of the shield was 0.0353 +- 0.03 mGY, while the absorbed dose was 0.0316+- 0.01 mGY when dosimeters mounted on the backside of  the shield .This shows a 10.4 % reduction which is statistically significant based on the T-test (p< 0.002).

Conclusion and recommendations:    The  use  of  the  thyroid  protecting   shield   has  a significant effect on reducing the thyroid gland absorbed dose during panoramic radiography and it’s use is strongly recommended.

Keywords: Thyroid gland, thyroid shield, panoramic radiography.
Full-Text [PDF 12 kb]   (4489 Downloads)    
Type of Study: original article | Subject: Radiology
Send email to the article author

Add your comments about this article
Your username or Email:

CAPTCHA


XML   Persian Abstract   Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Hafezi L, Mohammad Nejad T, Vejdannik S. Protective Effect of thyroid shield (AKTIF EP 316) on the absorbed dose of thyroid gland in panoramic radiography. J Res Dent Sci 2016; 13 (1) :8-13
URL: http://jrds.ir/article-1-720-en.html


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 13, Issue 1 (JRDS 2016) Back to browse issues page
مجله تحقیق در علوم دندانپزشکی Res Dent Sci
Persian site map - English site map - Created in 0.05 seconds with 38 queries by YEKTAWEB 4645