<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>journal of research in dental sciences</title>
<title_fa>مجله تحقیق در علوم دندانپزشکی</title_fa>
<short_title>J Res Dent Sci</short_title>
<subject>Medical Sciences</subject>
<web_url>http://jrds.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>2008-4676</journal_id_issn>
<journal_id_issn_online>2228-7353</journal_id_issn_online>
<journal_id_pii>8</journal_id_pii>
<journal_id_doi>10.66224/jrds</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>14</journal_id_sid>
<journal_id_nlai></journal_id_nlai>
<journal_id_science>13</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1395</year>
	<month>7</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2016</year>
	<month>10</month>
	<day>1</day>
</pubdate>
<volume>13</volume>
<number>3</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>مقایسه اثر دستگاه لایت کیور هالوژن با LED نسل دوم و سوم بر درجه پلی مریزاسیون 3 نوع کامپوزیت Bulk fill  در سطح فوقانی و تحتانی</title_fa>
	<title>Comparison  the effect of  halogen and 2th and 3th generation of  LED Light cure units  on degree of conversion (DC) of three  bulk fill composites at the top and bottom surfaces.</title>
	<subject_fa>ترمیمی</subject_fa>
	<subject>restorative dentistry</subject>
	<content_type_fa>مطالعه  اصیل</content_type_fa>
	<content_type>original article</content_type>
	<abstract_fa>&lt;h5 dir=&quot;RTL&quot;&gt;&lt;span style=&quot;font-family: arial;&quot;&gt;&lt;strong&gt;سابقه و هدف:&lt;/strong&gt; با توجه به اهمیت پلی مریزاسیون و خلاء اطلاعات در مورد مقایسه سه دستگاه لایت کیور متداول کشور و به منظور مقایسه تاثیر سه نوع دستگاه لایت کیور بر درجه پلی مریزاسیون سه نوع کامپوزیت &lt;span dir=&quot;LTR&quot;&gt;Bulk fill&lt;/span&gt;&amp;nbsp; در سطح و عمق این مطالعه انجام شد.&lt;/span&gt;&lt;/h5&gt;

&lt;h5 dir=&quot;RTL&quot;&gt;&lt;span style=&quot;font-family: arial;&quot;&gt;&lt;strong&gt;مواد و روش ها&lt;/strong&gt;: در این مطالعه تجربی- آزمایشگاهی از 3 نوع دستگاه لایت کیور شامل &lt;span dir=&quot;LTR&quot;&gt;Astralis 7&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt; (&lt;/span&gt;هالوژن&lt;span dir=&quot;LTR&quot;&gt;) &lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;Pen Cure(LED&lt;/span&gt; نسل دوم) و &lt;span dir=&quot;LTR&quot;&gt;Blue&lt;/span&gt; &lt;span dir=&quot;LTR&quot;&gt;phase N(LED&lt;/span&gt; نسل سوم) و سه نوع کامپوزیت &lt;span dir=&quot;LTR&quot;&gt;Bulk fill&lt;/span&gt; شامل&lt;span dir=&quot;LTR&quot;&gt;Tetric Evocerambulk fill (Ivoclar)&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt; - &lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;Filtek Bulk&lt;/span&gt; &lt;span dir=&quot;LTR&quot;&gt;fill&lt;/span&gt; &amp;nbsp;&amp;nbsp;&lt;span dir=&quot;LTR&quot;&gt;(3M) , X-trafill (VOCO)&lt;/span&gt;&amp;nbsp; استفاده شد&lt;span dir=&quot;LTR&quot;&gt;.&lt;/span&gt;&lt;/span&gt;&lt;/h5&gt;

&lt;h5 dir=&quot;RTL&quot;&gt;&lt;span style=&quot;font-family: arial;&quot;&gt;سیلندرهای کامپوزیتی به قطر 5 میلی متر و ضخامت 4 میلی متر تهیه و سپس توسط دستگاه های لایت کیور طبق دستور کارخانه سازنده کیور شدند. (روی سطح کامپوزیت ها قبل از کیور کردن با یک نوار سلولوئیدی شفاف جهت جلوگیری از تشکیل لایه محافظ اکسیژن(&lt;span dir=&quot;LTR&quot;&gt;inhibited layer&lt;/span&gt;) پوشانده شد. سپس نمونه ها 24 ساعت در آب 37درجه سانتی گراد و در انکوباتور بدور از نور محیط نگه داری شد. و بعد از 24 ساعت میزان درجه پلی مریزاسیون سطح فوقانی و تحتانی (4 میلی متری) نمونه ها توسط دستگاه &lt;span dir=&quot;LTR&quot;&gt;FTIR&lt;/span&gt; اندازه گیری شد. داده ها با آنالیز آماری &lt;span dir=&quot;LTR&quot;&gt;Kruscall &amp;ndash;wallis&lt;/span&gt; و &lt;span dir=&quot;LTR&quot;&gt;Mann-U-Whithney&lt;/span&gt; مورد ارزیابی قرار گرفت.&lt;/span&gt;&lt;/h5&gt;

&lt;h5 dir=&quot;RTL&quot;&gt;&lt;span style=&quot;font-family: arial;&quot;&gt;&lt;strong&gt;یافته ها:&lt;/strong&gt; نتایج نشان داد که میزان درجه پلی مریزاسیون ناشی از کیور شدن توسط هر 3 دستگاه &lt;span dir=&quot;LTR&quot;&gt;Blue phase N (LED III) PEN Cure (LED II) &amp;ndash; Astralis7 (QTH) &lt;/span&gt;&amp;nbsp;در سطح هر سه نوع کامپوزیت &lt;span dir=&quot;LTR&quot;&gt;Bulk fill&lt;/span&gt; مورد استفاده تفاوت معنی داری با هم نداشتند. (2/0&gt;&lt;span dir=&quot;LTR&quot;&gt;P&lt;/span&gt;) اما&amp;nbsp; میزان درجه پلی مریزاسیون سطح تحتانی (4 میلی متری) هر سه نوع کامپوزیت که با&lt;span dir=&quot;LTR&quot;&gt; (LED lll) (QTh)&lt;/span&gt; کیور شده بودند به طور معنی داری بیشتر از کامپوزیتهای&amp;nbsp; کیور شده با&lt;span dir=&quot;LTR&quot;&gt; (&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;LED II)&lt;/span&gt; بودند. (001/0&gt;&lt;span dir=&quot;LTR&quot;&gt;P&lt;/span&gt;) &amp;nbsp;ضمنا میزان درجه پلی مریزاسیون سطوح فوقانی و تحتانی کیور شده با هر سه نوع دستگاه لایت کیور (&lt;span dir=&quot;LTR&quot;&gt;LED III) (LED&amp;nbsp; II) (QTH&lt;/span&gt;) قابل قبول و بالاتر از حد پایه درجه پلی مریزاسیون (55%=&lt;span dir=&quot;LTR&quot;&gt;DC&lt;/span&gt;) بود.&lt;/span&gt;&lt;/h5&gt;

&lt;p dir=&quot;RTL&quot;&gt;&lt;span style=&quot;font-family: arial;&quot;&gt;&lt;strong&gt;نتیجه گیری:&lt;/strong&gt; به نظر می رسد که هر سه نوع کامپوزیت &lt;span dir=&quot;LTR&quot;&gt;Bulk fill&lt;/span&gt; مورد مطالعه توسط هر سه نوع دستگاه لایت کیور هالوژن &amp;ndash;&lt;span dir=&quot;LTR&quot;&gt;LED&lt;/span&gt; نسل دوم و &lt;span dir=&quot;LTR&quot;&gt;LED&lt;/span&gt; نسل سوم هم در سطح و هم در عمق 4 میلی متری به میزان قابل قبول از نظر کلینیکی کیور شدند.&lt;/span&gt;&lt;/p&gt;

&lt;h5 dir=&quot;RTL&quot;&gt;&lt;span style=&quot;font-family: arial;&quot;&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/span&gt;&lt;/h5&gt;
</abstract_fa>
	<abstract>&lt;p style=&quot;margin: 0cm 0cm 0pt; text-align: justify; line-height: 150%; -ms-text-justify: kashida; text-kashida: 0%;&quot;&gt;&lt;font color=&quot;#000000&quot;&gt;&lt;b&gt;&lt;span b=&quot;&quot; new=&quot;&quot; style=&quot;line-height: 150%; font-family:;&quot; times=&quot;&quot;&gt;Background &amp; aim&lt;/span&gt;&lt;/b&gt;&lt;span b=&quot;&quot; new=&quot;&quot; style=&quot;line-height: 150%; font-family:;&quot; times=&quot;&quot;&gt;: regarding to importance of polymerization and information deficiency about comparison of three conventional light cure Iranian devices, this study was purposed to compare the effect of three Light cure unite to degree of conversion (DC) of three bulk fill composites at the top and bottom surfaces.&lt;/span&gt;&lt;/font&gt;&lt;/p&gt;

&lt;p style=&quot;margin: 0cm 0cm 0pt; text-align: justify; line-height: 150%; -ms-text-justify: kashida; text-kashida: 0%;&quot;&gt;&lt;font color=&quot;#000000&quot;&gt;&lt;b&gt;&lt;span b=&quot;&quot; new=&quot;&quot; style=&quot;line-height: 150%; font-family:;&quot; times=&quot;&quot;&gt;Material &amp; Methods&lt;/span&gt;&lt;/b&gt;&lt;span b=&quot;&quot; new=&quot;&quot; style=&quot;line-height: 150%; font-family:;&quot; times=&quot;&quot;&gt;: in this experimental in vitro study, light cure units including astralis 7 (QTH), pencur (J.MORRITA)(second generation of LED) and blue phas N (Ivoclar)(third generation of LED) and three bulk fill resin composites including tetric evoceram bulk fill (Ivoclar), x-trafill (voco) and filtek bulk fill (3m) and were investigated. Cylindrical composites with5 mm diameter and 4 mm widthness were performed and cured regarding to manufacture instruction. Before curing, composites were covered by with transparent celoloid membrane in order to formation of inhibition layer. Degree of conversion (DC) was assessed by FTIR device. DC was measured for samples on top and bottom surface after 24 h storage period at 37c (n=5). Results were analysed using Kruskal Wallis and Mann-u-Whitney tests. &lt;/span&gt;&lt;/font&gt;&lt;/p&gt;

&lt;p style=&quot;margin: 0cm 0cm 0pt; text-align: justify; line-height: 150%; -ms-text-justify: kashida; text-kashida: 0%;&quot;&gt;&lt;font color=&quot;#000000&quot;&gt;&lt;b&gt;&lt;span b=&quot;&quot; new=&quot;&quot; style=&quot;line-height: 150%; font-family:;&quot; times=&quot;&quot;&gt;Results&lt;/span&gt;&lt;/b&gt;&lt;span b=&quot;&quot; new=&quot;&quot; style=&quot;line-height: 150%; font-family:;&quot; times=&quot;&quot;&gt;: at the top surface there were no significant difference between the unites of light cures in %DC.(p&lt;0.2) but at the bottom surface the QTH and third generation of LED (poly wave) had significant difference to second Generation of LED (mono wave). (p&lt;0.001) Also, polymerization degrees of top and bottom surfaces were acceptable a more than basic level of 55%. &lt;/span&gt;&lt;/font&gt;&lt;/p&gt;

&lt;p style=&quot;margin: 0cm 0cm 0pt; text-align: justify; line-height: 150%; -ms-text-justify: kashida; text-kashida: 0%;&quot;&gt;&lt;font color=&quot;#000000&quot;&gt;&lt;b&gt;&lt;span b=&quot;&quot; new=&quot;&quot; style=&quot;line-height: 150%; font-family:;&quot; times=&quot;&quot;&gt;Conclusion&lt;/span&gt;&lt;/b&gt;&lt;span b=&quot;&quot; new=&quot;&quot; style=&quot;line-height: 150%; font-family:;&quot; times=&quot;&quot;&gt;: All three Bulk fill composites were cured successfully with three light cure units both in top and bottom surfaces.&lt;/span&gt;&lt;/font&gt;&lt;/p&gt;

&lt;p style=&quot;margin: 0cm 0cm 0pt; text-align: justify; line-height: 150%; -ms-text-justify: kashida; text-kashida: 0%;&quot;&gt;&lt;/p&gt;
</abstract>
	<keyword_fa>لایت کیور (QTH), LED, درجه پلی مریزاسیون, کامپوزیت رزین, FTIR</keyword_fa>
	<keyword>Halogen (QTH) , LED , Degree of conversion Bluk fill, FTIR.</keyword>
	<start_page>149</start_page>
	<end_page>155</end_page>
	<web_url>http://jrds.ir/browse.php?a_code=A-10-1122-1&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>M</first_name>
	<middle_name></middle_name>
	<last_name>SADAGHIANI</last_name>
	<suffix></suffix>
	<first_name_fa>مراد</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>صدقیانی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>100319475328460010542</code>
	<orcid>100319475328460010542</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>دانشگاه آزاد اسلامی - واحددندانپزشکی</affiliation_fa>
	 </author>


	<author>
	<first_name>S</first_name>
	<middle_name></middle_name>
	<last_name>Nemati Anaraki </last_name>
	<suffix></suffix>
	<first_name_fa>سعید</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>نعمتی انارکی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>100319475328460010543</code>
	<orcid>100319475328460010543</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>دانشگاه آزاد اسلامی - واحددندانپزشکی</affiliation_fa>
	 </author>


	<author>
	<first_name>R</first_name>
	<middle_name></middle_name>
	<last_name>Maheri</last_name>
	<suffix></suffix>
	<first_name_fa>رامین</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>ماهری</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>DR_RAMA_75@YAHOO.COM</email>
	<code>100319475328460010544</code>
	<orcid>100319475328460010544</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>دانشگاه آزاد اسلامی - واحددندانپزشکی</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
