<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>journal of research in dental sciences</title>
<title_fa>مجله تحقیق در علوم دندانپزشکی</title_fa>
<short_title>J Res Dent Sci</short_title>
<subject>Medical Sciences</subject>
<web_url>http://jrds.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>2008-4676</journal_id_issn>
<journal_id_issn_online>2228-7353</journal_id_issn_online>
<journal_id_pii>8</journal_id_pii>
<journal_id_doi>10.66224/jrds</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>14</journal_id_sid>
<journal_id_nlai></journal_id_nlai>
<journal_id_science>13</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1396</year>
	<month>1</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2017</year>
	<month>4</month>
	<day>1</day>
</pubdate>
<volume>14</volume>
<number>1</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>مقایسه تاثیر سه سیستم ایمپلنت بر میزان شل شدن پیچ اباتمنت</title_fa>
	<title>Comparison of the screw loosening in three implants systems</title>
	<subject_fa>پروتز</subject_fa>
	<subject>Prothesis</subject>
	<content_type_fa>مطالعه  اصیل</content_type_fa>
	<content_type>original article</content_type>
	<abstract_fa>&lt;h5 dir=&quot;RTL&quot;&gt;&lt;strong&gt;سابقه و هدف:&lt;/strong&gt; در کنار تنوع سیستم های ایمپلنت بسیاری از شرکت ها اقدام به ساخت اجزایی مشابه اجزای قطعات سیستم های ایمپلنتی رایج کرده و ادعا نموده اند که تطابق کاملی با آن دارند. هدف از انجام این مطالعه مقایسه میزان شل شدن پیچ اباتمنت های سیستم &lt;span dir=&quot;LTR&quot;&gt;ITI&lt;/span&gt;&amp;nbsp;&amp;nbsp; و سیستم های مشابه آن است .&lt;/h5&gt;

&lt;h5 dir=&quot;RTL&quot;&gt;&lt;strong&gt;مواد و روش ها:&lt;/strong&gt; در این تحقیق که &amp;nbsp;بر روی 30 عدد دامی ایمپلنت &amp;nbsp;&lt;span dir=&quot;LTR&quot;&gt;ITI&amp;nbsp; &lt;/span&gt;&amp;nbsp;&amp;nbsp;انجام شد، 10 عدد اباتمنت سیستم &lt;span dir=&quot;LTR&quot;&gt;ITI&lt;/span&gt; و 10 عدد اباتمنت سیستم&amp;nbsp; &lt;span dir=&quot;LTR&quot;&gt;COWELL&lt;/span&gt; و 10 عدد اباتمنت &lt;span dir=&quot;LTR&quot;&gt;E&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;uroteknika&lt;/span&gt;&amp;nbsp; بسته شد مجموعه با دستگاه تورکمتر تورک داده شد،&amp;nbsp;&amp;nbsp; میزان &lt;span dir=&quot;LTR&quot;&gt;RTV&lt;/span&gt;&amp;nbsp; اولیه با همان دستگاه اندازه گیری شده و مجددا تا 35 نیوتن ثابت شد و در بلوک های آکریلی مانت شده و در دستگاه &lt;span dir=&quot;LTR&quot;&gt;cyclic load&lt;/span&gt;&amp;nbsp; تحت نیروی 75 نیوتن بر سانتی متر&amp;nbsp; با فرکانس 50000&amp;nbsp; دور در دقیقه قرار گرفت&amp;nbsp; &lt;span dir=&quot;LTR&quot;&gt;RTV&lt;/span&gt;&amp;nbsp; نهایی مجدا اندازه گرفته شد نتایج بدست آمده باانالیز &lt;span dir=&quot;LTR&quot;&gt;ANOVA&lt;/span&gt;&amp;nbsp; مورد بررسی قرار گرفت.&lt;/h5&gt;

&lt;p dir=&quot;RTL&quot;&gt;&lt;/p&gt;

&lt;p dir=&quot;RTL&quot;&gt;&amp;nbsp;&lt;strong&gt;یافته ها&lt;/strong&gt;: میزان &lt;span dir=&quot;LTR&quot;&gt;RTV&lt;/span&gt; اولیه در اباتمنت های&amp;nbsp; &lt;span dir=&quot;LTR&quot;&gt;ITI&lt;/span&gt; &amp;nbsp;&amp;nbsp;&amp;nbsp;قبل از بارگذاری &lt;span dir=&quot;LTR&quot;&gt;N/Cm&lt;/span&gt; 26/2&amp;plusmn;7/30&amp;nbsp; و بعد از بارگذاری به &lt;span dir=&quot;LTR&quot;&gt;N/Cm&lt;/span&gt; 0/23 کاهش یافت این میزان در سیستم &amp;nbsp;&lt;span dir=&quot;LTR&quot;&gt;Euroteknika&lt;/span&gt; قبل و بعد از بارگذاری به ترتیب&lt;br&gt;
&lt;span dir=&quot;LTR&quot;&gt;N/Cm&lt;/span&gt; 6/2&lt;span dir=&quot;LTR&quot;&gt;&amp;plusmn;&lt;/span&gt;1/29&amp;nbsp; و&amp;nbsp; 0/21&amp;nbsp; و در سیستم &lt;span dir=&quot;LTR&quot;&gt;COWELL&lt;/span&gt; &amp;nbsp;&lt;span dir=&quot;LTR&quot;&gt;N/Cm&lt;/span&gt; 61/3&amp;plusmn;2/29 و 41/2&amp;plusmn;6/21 بدست آمد. مقادیر &lt;span dir=&quot;LTR&quot;&gt;RTV&lt;/span&gt; &amp;nbsp;بعد از بار گذاری دوره&lt;span dir=&quot;LTR&quot;&gt;&amp;shy;&lt;/span&gt;ایی در گروه های مختلف با یکدیگر تفاوت معنا داری نداشت.&lt;/p&gt;

&lt;h5 dir=&quot;RTL&quot;&gt;&lt;strong&gt;نتیجه گیری:&lt;/strong&gt; به نظر می رسد 3 &amp;nbsp;نوع اباتمنت &amp;nbsp;مورد بررسی (&lt;span dir=&quot;LTR&quot;&gt;ITI,COWELL,Euroteknika&lt;/span&gt; )در شرایط مشابه از نظر میزان شل شدن پیچ اباتمنت ندارند.&lt;/h5&gt;

&lt;p dir=&quot;RTL&quot;&gt;&lt;/p&gt;

&lt;h5 dir=&quot;RTL&quot;&gt;&lt;/h5&gt;
</abstract_fa>
	<abstract>&lt;p&gt;&lt;strong&gt;Background and Aim:&amp;nbsp; &lt;/strong&gt;Along with variety of implant systems,&amp;nbsp; some manufacturers produced similar components for the main implant systems and&lt;/p&gt;

&lt;p&gt;claimed them to be completely compatible with the main systems which&lt;/p&gt;

&lt;p&gt;require more studies in this regard. Objective the aim of present study was to compare screw loosening in ITI and its compatible systems.&lt;/p&gt;

&lt;p&gt;&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;Materials and Methods:&lt;/strong&gt;In this in vitro trial, 10 implants of&amp;nbsp; ITI original and 10 abutments of the Cowell&lt;/p&gt;

&lt;p&gt;and 10 Euroteknika systems were connected to ITI implants. abutment screw was tightened by 35 N/CM torque. After 5 minutes, the initial RTV of the specimens were measured. The connections were subjected to the cyclic loading (load of 75 N and 1 Hz) for&amp;nbsp; 500000 cycles. Postcyclic&amp;nbsp; RTV were measured by the torque wrench and the data were evaluated by ANOVA analyzing test.&lt;/p&gt;

&lt;p&gt;&lt;/p&gt;

&lt;p&gt;Results:In ITI abutments; RTV was 30.7&amp;plusmn;2.26 and &lt;span dir=&quot;RTL&quot;&gt;23&lt;/span&gt;/0 N/CM before and after&lt;/p&gt;

&lt;p&gt;cyclic loading. In Euroteknika abutments, RTV was 29.1&amp;plusmn;2.6 and &lt;span dir=&quot;RTL&quot;&gt;21&lt;/span&gt;/0&lt;/p&gt;

&lt;p&gt;N/CM before and after cyclic loading. In Cowell system; RTV was decreased&lt;/p&gt;

&lt;p&gt;from 29.2&amp;plusmn;3.61 to 2&lt;span dir=&quot;RTL&quot;&gt;1&lt;/span&gt;.6&lt;span dir=&quot;RTL&quot;&gt;41/2&lt;/span&gt;&lt;span dir=&quot;RTL&quot;&gt;&amp;plusmn;&lt;/span&gt; N/CM before and after cyclic loading. No&lt;/p&gt;

&lt;p&gt;significant differences were found regarding post-cyclic RTV in different&lt;/p&gt;

&lt;p&gt;abutment/implant connections.&lt;/p&gt;

&lt;p&gt;&lt;/p&gt;

&lt;p&gt;Conclusion:It seems , Under Similar Condition, the abutment brands of ITI, Euroteknika and&lt;/p&gt;

&lt;p&gt;Cowell connected to ITI implant system did not significantly affected screw&lt;/p&gt;

&lt;p&gt;loosening values following cyclic loading.&lt;/p&gt;

&lt;p&gt;&lt;/p&gt;

&lt;p&gt;&lt;/p&gt;

&lt;p&gt;&lt;/p&gt;

&lt;p&gt;&lt;/p&gt;
</abstract>
	<keyword_fa>ایمپلنت دندانی, تورک, بارگذاری ایمپلنت دندانی</keyword_fa>
	<keyword>Dental implant,torque,dental implant loading</keyword>
	<start_page>1</start_page>
	<end_page>6</end_page>
	<web_url>http://jrds.ir/browse.php?a_code=A-10-1116-2&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>F</first_name>
	<middle_name></middle_name>
	<last_name>Farid</last_name>
	<suffix></suffix>
	<first_name_fa>فرزانه</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>فرید</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>100319475328460011223</code>
	<orcid>100319475328460011223</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>دانشگاه گیلان</affiliation_fa>
	 </author>


	<author>
	<first_name>H</first_name>
	<middle_name></middle_name>
	<last_name>Haj mir agha</last_name>
	<suffix></suffix>
	<first_name_fa>حبیب</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>حاج میر آقا</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>100319475328460011224</code>
	<orcid>100319475328460011224</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>دانشگاه تهران</affiliation_fa>
	 </author>


	<author>
	<first_name>I</first_name>
	<middle_name></middle_name>
	<last_name>Poornasiri</last_name>
	<suffix></suffix>
	<first_name_fa>ایلناز</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>پورنصیری</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>pournasiri_elnaz@yahoo.com</email>
	<code>100319475328460011225</code>
	<orcid>100319475328460011225</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>دانشگاه گیلان</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
