<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>journal of research in dental sciences</title>
<title_fa>مجله تحقیق در علوم دندانپزشکی</title_fa>
<short_title>J Res Dent Sci</short_title>
<subject>Medical Sciences</subject>
<web_url>http://jrds.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>2008-4676</journal_id_issn>
<journal_id_issn_online>2228-7353</journal_id_issn_online>
<journal_id_pii>8</journal_id_pii>
<journal_id_doi>10.66224/jrds</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>14</journal_id_sid>
<journal_id_nlai></journal_id_nlai>
<journal_id_science>13</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1394</year>
	<month>12</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2016</year>
	<month>3</month>
	<day>1</day>
</pubdate>
<volume>13</volume>
<number>1</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>بررسی تاثیر محافظ تیروئید  AKTIF EP 316 بر میزان دوز جذبی غده تیروئید در رادیوگرافی  پانورامیک</title_fa>
	<title>Protective Effect of thyroid shield (AKTIF EP 316) on the absorbed dose of thyroid gland in panoramic radiography</title>
	<subject_fa>رادیولوژی</subject_fa>
	<subject>Radiology</subject>
	<content_type_fa>مطالعه  اصیل</content_type_fa>
	<content_type>original article</content_type>
	<abstract_fa>&lt;p dir=&quot;RTL&quot;&gt;&lt;strong&gt;خلاصه&lt;/strong&gt;&lt;span dir=&quot;LTR&quot;&gt;:&lt;/span&gt;&lt;/p&gt;

&lt;p dir=&quot;RTL&quot;&gt;&lt;strong&gt;سابقه و هدف:&lt;/strong&gt; در رادیوگرافی پانورامیک محافظ تیروئید بدلیل ایجاد ارتیفکت بطور روتین استفاده نمی شود. در این مطالعه بر انیم تا&amp;nbsp; تاثیر استفاده نوع خاصی از شیلد محافظ ( &lt;span dir=&quot;LTR&quot;&gt;AKTIF EP 316&lt;/span&gt; )&amp;nbsp; را بر دوز جذبی غده تیروئید مراجعین به یک کلینیک خصوصی شهر تهران در سال 93-1392 مورد بررسی قرار دهیم.&lt;/p&gt;

&lt;p dir=&quot;RTL&quot;&gt;&lt;strong&gt;مواد و روش&#8204;ها:&lt;/strong&gt; این تحقیق با طراحی کارآزمایی بالینی بر روی 20 مرد که از لحاظ قد , وزن و سن همسان بوده و&amp;nbsp; دستور تهیه رادیوگرافی&amp;nbsp; پانورامیک داشتند انجام شد . دوزیمترها به صورت علامت + بر رو و زیر شیلد محافظ تیروئید قرار گرفتند. سپس محافظ برای10 نفر از افراد&amp;nbsp; استفاده و&amp;nbsp; رادیوگرافی&amp;nbsp; پانورامیک&amp;nbsp; با&amp;nbsp; شرایط یکسان &lt;span dir=&quot;LTR&quot;&gt;kvp&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;= 72 , &lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;MA&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;=10&lt;/span&gt;&amp;nbsp; و زمان 18ثانیه توسط دستگاه &lt;span dir=&quot;LTR&quot;&gt;SOREDEX&lt;/span&gt; مدل&lt;span dir=&quot;LTR&quot;&gt;D&amp;nbsp; &lt;/span&gt;&amp;nbsp;&lt;span dir=&quot;LTR&quot;&gt;CRANEX-&lt;/span&gt;&amp;nbsp; تهیه گردید. این عمل برای&amp;nbsp; 10بیمار دیگربا سری دیگری دوزیمتر نیز انجام شد.&lt;span dir=&quot;LTR&quot;&gt;TLD&lt;/span&gt;ها جهت قرائت به سازمان انرژی اتمی فرستاده شدند. نتایج با ازمون فیشرو &lt;span dir=&quot;LTR&quot;&gt;T- test&lt;/span&gt; ارزیابی گردید.&lt;/p&gt;

&lt;p dir=&quot;RTL&quot;&gt;&lt;strong&gt;یافته&#8204;ها&lt;/strong&gt;: میزان&amp;nbsp; دوز جذبی غده تیروئید هنگامی که دوزیمتر روی شیلد قرار گرفته بود برابر&amp;nbsp; با&amp;nbsp; 03/0&amp;plusmn;0353/0 میلی گری و هنگامی که دوزیمتر زیر شیلد قرار گرفت 01/0&amp;plusmn;0316/0 میلی گری&amp;nbsp; اندازه گیری شد.&amp;nbsp; که باعث 4/10 درصدی کاهش دوز جذبی غده تیروئید شد و این اختلاف از لحاظ آماری معنی&amp;shy;دار بود. (002/0&gt;&lt;span dir=&quot;LTR&quot;&gt;P&lt;/span&gt;)&lt;/p&gt;

&lt;p dir=&quot;RTL&quot;&gt;&lt;strong&gt;نتیجه&#8204;گیری:&lt;/strong&gt; با&amp;nbsp; توجه&amp;nbsp; به قانون&amp;nbsp; &lt;span dir=&quot;LTR&quot;&gt;ALARA&lt;/span&gt;&amp;nbsp; و کاهش 4/10 درصدی دوز جذبی غده تیروئید، استفاده از این نوع محافظ تیروئید هنگام&amp;nbsp; رادیوگرافی پانورامیک توصیه می شود.&lt;/p&gt;
</abstract_fa>
	<abstract>&lt;p dir=&quot;RTL&quot; style=&quot;text-align: left;&quot;&gt;&lt;strong&gt;&lt;u&gt;&lt;span dir=&quot;LTR&quot;&gt;Background and aim&lt;/span&gt;&lt;/u&gt;&lt;/strong&gt;&lt;strong&gt;&lt;span dir=&quot;LTR&quot;&gt;:&amp;nbsp;&amp;nbsp; protecting&amp;nbsp;&amp;nbsp; the&amp;nbsp; thyroid&amp;nbsp;&amp;nbsp; gland&amp;nbsp;&amp;nbsp; during panoramic radiography with shielding is not recommended. in this study ,the effect of&amp;nbsp; using&amp;nbsp; thyroid&amp;nbsp; protecting&amp;nbsp; shield&amp;nbsp; ( AKTIF EP 316 )&amp;nbsp; on thyroid dose of patients&amp;nbsp; visiting&amp;nbsp; a&amp;nbsp; private clinic in Tehran in 1392-93 was investigated&lt;/span&gt;&lt;/strong&gt;&lt;/p&gt;

&lt;p dir=&quot;RTL&quot; style=&quot;text-align: left;&quot;&gt;&lt;/p&gt;

&lt;p dir=&quot;RTL&quot; style=&quot;text-align: left;&quot;&gt;&lt;strong&gt;&lt;u&gt;&lt;span dir=&quot;LTR&quot;&gt;Materials and methods&lt;/span&gt;&lt;/u&gt;&lt;/strong&gt;&lt;strong&gt;&lt;span dir=&quot;LTR&quot;&gt;:&amp;nbsp; In&amp;nbsp; this&amp;nbsp; clinical&amp;nbsp; trial&amp;nbsp; study&amp;nbsp; 20 men&amp;nbsp; with similar height, weight and age were&amp;nbsp; selected among patients whom prescribed panoramic radiography. The dosimeters ( TLDs) were placed on&amp;nbsp; the&amp;nbsp; front and back side of shield and radiography was performed with&amp;nbsp; similar conditions (MA=10 , KVP=72-76 , 18 s time) using a CRANEX D&amp;nbsp; machine and done for every 10 patients with similar series of dosimeters. Then the&amp;nbsp; TLDs &amp;nbsp;were read and data&amp;#39;s were evaluated by Fischer exact test and T- test.&lt;/span&gt;&lt;/strong&gt;&lt;/p&gt;

&lt;p dir=&quot;RTL&quot; style=&quot;text-align: left;&quot;&gt;&lt;/p&gt;

&lt;p dir=&quot;RTL&quot; style=&quot;text-align: left;&quot;&gt;&lt;strong&gt;&lt;u&gt;&lt;span dir=&quot;LTR&quot;&gt;Results&lt;/span&gt;&lt;/u&gt;&lt;/strong&gt;&lt;strong&gt;&lt;span dir=&quot;LTR&quot;&gt;: All the&amp;nbsp; images were&amp;nbsp; assessed with the Fischer test , were acceptable and the thyroid protecting shield did not&amp;nbsp; prevent the visualization of the anterior teeth. The absorbed dose of thyroid gland when the dosimeters mounted on the front side of the shield was 0.0353 +- 0.03 mGY, while the absorbed dose was 0.0316+- 0.01 mGY when dosimeters mounted on the backside of&amp;nbsp; the shield .This shows a 10.4 % reduction which is statistically significant based on the T-test (p&lt; 0.002).&lt;/span&gt;&lt;/strong&gt;&lt;/p&gt;

&lt;p dir=&quot;RTL&quot; style=&quot;text-align: left;&quot;&gt;&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;&lt;u&gt;Conclusion and recommendations&lt;/u&gt;:&amp;nbsp;&amp;nbsp;&amp;nbsp; The&amp;nbsp; use&amp;nbsp; of&amp;nbsp; the&amp;nbsp; thyroid&amp;nbsp; protecting&amp;nbsp;&amp;nbsp; shield&amp;nbsp;&amp;nbsp; has&amp;nbsp; a significant effect on reducing the thyroid gland absorbed dose during panoramic radiography and it&amp;rsquo;s use is strongly recommended.&lt;/strong&gt;&lt;/p&gt;
</abstract>
	<keyword_fa>رادیوگرافی پانورامیک,غده تیروئید, محافظ سربی</keyword_fa>
	<keyword>Thyroid gland, thyroid shield, panoramic radiography.</keyword>
	<start_page>8</start_page>
	<end_page>13</end_page>
	<web_url>http://jrds.ir/browse.php?a_code=A-10-1075-1&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>L</first_name>
	<middle_name></middle_name>
	<last_name>Hafezi</last_name>
	<suffix></suffix>
	<first_name_fa>لادن</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>حافظی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>10031947532846009377</code>
	<orcid>10031947532846009377</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Dental</affiliation>
	<affiliation_fa>Dental</affiliation_fa>
	 </author>


	<author>
	<first_name>T</first_name>
	<middle_name></middle_name>
	<last_name>Mohammad Nejad</last_name>
	<suffix></suffix>
	<first_name_fa>تیبا</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>محمد نژاد</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>10031947532846009378</code>
	<orcid>10031947532846009378</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Dental</affiliation>
	<affiliation_fa>Dental</affiliation_fa>
	 </author>


	<author>
	<first_name>S</first_name>
	<middle_name></middle_name>
	<last_name>Vejdannik</last_name>
	<suffix></suffix>
	<first_name_fa>سیما</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>وجدان نیک</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>30ma.gemini@gmail.com</email>
	<code>10031947532846009379</code>
	<orcid>10031947532846009379</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>	Post Graduate Student of maxillofacial Radiology department, Dental branch, Islamic Azad University, Tehran. Iran</affiliation>
	<affiliation_fa>دستیار تخصصی بخش رادیولوژی، دانشگاه آزاد اسلامی واحد دندانپزشکی تهران</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
