<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>journal of research in dental sciences</title>
<title_fa>مجله تحقیق در علوم دندانپزشکی</title_fa>
<short_title>J Res Dent Sci</short_title>
<subject>Medical Sciences</subject>
<web_url>http://jrds.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>2008-4676</journal_id_issn>
<journal_id_issn_online>2228-7353</journal_id_issn_online>
<journal_id_pii>8</journal_id_pii>
<journal_id_doi>10.66224/jrds</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>14</journal_id_sid>
<journal_id_nlai></journal_id_nlai>
<journal_id_science>13</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1390</year>
	<month>11</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2012</year>
	<month>2</month>
	<day>1</day>
</pubdate>
<volume>8</volume>
<number>4</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>مقایسه تاثیر آلژینات آریادنت با بایر بر میزان دقت ابعادی</title_fa>
	<title>Comparison of the Dimensional Changes of Ariadent and Bayer Alginate Impression Materials (Invitro)</title>
	<subject_fa>جراحی-</subject_fa>
	<subject>oral surgery</subject>
	<content_type_fa>مطالعه  اصیل</content_type_fa>
	<content_type>original article</content_type>
	<abstract_fa>&lt;p align=&quot;right&quot;&gt;&lt;sup&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/sup&gt;&lt;/p&gt;&lt;p align=&quot;right&quot;&gt;&lt;strong&gt;&lt;/strong&gt;خلاصه : سابقه و هدف: با توجه به شیوع تغییر ابعادی قالب‌ها و تبعات آن و مصرف آلژینات‌های داخلی در سطح وسیع، این تحقیق جهت تعیین دقت ابعادی آلژینات آریادنت به عنوان نمونه داخلی و بایر به عنوان نمونه خارجی انجام شد. مواد و روش‌ها: تحقیق با طراحی تجربی روی 17 نمونه آلژینات‌ها آریادنت (مورد) و بایر (شاهد) انجام گرفت. مدلی ساخته و قالبگیری از مدل اصلی توسط قاشقک اختصاصی با آلژینات های آریادنت و بایر انجام و قالب‌ها با گچ استون ریخته شد،کوچکترین و بزرگترین قطر، ارتفاع و فاصله بین دای‌ها با دستگاه اندازه گیری میکروسکوپی ( Integral Derby England ) سنجیده وداده‌ها با آزمون‌های paired T Test و Mann-Whitney مورد قضاوت آماری قرار گرفت. یافته‌ها: تفاوت قطر کوچک وبزرگ، ارتفاع و فاصله محورهای دو دای کست حاصل از آلژینات بایر به ترتیب برابر با ، 6/185 ± 2/209 ، 7/230 ± 5/345 ، 1/213 ± 9/219 و 7/478 ± 3/328 میکرون و درآلژینات آریادنت به ترتیب برابر با ، 5 / 215 ± 3/198 ، 3/227 ± 8/342 ، 9/280 ± 7/336 و 5/265 ± 9/281 میکرون بود که هر دو نسبت به نمونه اصلی اختلاف معنی‌داری داشتند ( 0005/0 P &lt; ). میزان تغییرات ابعادی دو نوع آلژینات، آلژینات بیار و آریادنت در مقایسه با یکدیگر معنی دار نبود (9/0 &lt; P ). نتیجه‌گیری: دو ماده تغییرات ابعادی معنی‌دار نسبت به مدل اصلی داشتند که در پروتز ثابت عدم کاربرد اما برای قالب‌گیری نهایی پروتز متحرک قابل استفاده است. &lt;/p&gt;&lt;p align=&quot;right&quot;&gt;  &lt;/p&gt;&lt;p align=&quot;right&quot;&gt;کلید واژه ها: ماده قالب گیری دندانی، هیدروکلوئید غیرقابل برگشت، تغییرات ابعادی &lt;/p&gt;</abstract_fa>
	<abstract>&lt;p&gt; &lt;strong&gt; Comparison of the Dimensional Changes of Ariadent and Bayer Alginate Impression Materials (Invitro) &lt;/strong&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/p&gt;&lt;p&gt; &lt;strong&gt; &lt;/strong&gt;&lt;/p&gt;&lt;p&gt; &lt;strong&gt; &lt;/strong&gt;    &lt;/p&gt;&lt;p&gt; &lt;strong&gt; Abstract: &lt;/strong&gt;&lt;/p&gt;&lt;p&gt; &lt;strong&gt; &lt;/strong&gt;&lt;/p&gt;&lt;p&gt; &lt;strong&gt; Background and Aim: &lt;/strong&gt;: Dimensional changes of impression materials cause distortion of the cast with negative impact on the outcomes of prosthodontics treatments. There is less evidence about accuracy of the domestic alginate impression materials.The aim of this study was to compare the dimensional changes of Ariadent and Bayer alginate impression materials.&lt;strong&gt;&lt;/strong&gt; &lt;/p&gt;&lt;p&gt; &lt;strong&gt; &lt;/strong&gt;&lt;/p&gt;&lt;p&gt; &lt;strong&gt; Materials and Methods &lt;/strong&gt;In this experimental study, seventeen casts were made from master model by a cast metallic special tray, using Ariadent (case) and Bayer (control) alginates. Small and large diameter, height and distance of two dies were measured by a digital measuring instruments. Data were collected and analyzed by Paired T –Test, and MannWhittney for the two groups and master model.&lt;strong&gt;&lt;/strong&gt; &lt;/p&gt;&lt;p&gt; &lt;strong&gt; &lt;/strong&gt;&lt;/p&gt;&lt;p&gt; &lt;strong&gt; Results: &lt;/strong&gt;The difference between the size of small and large diameter, height, and distance of centers of two dies made from Bayer alginate was 209.2 ± 185.6, 345.5 ± 230.7, 219.9 ± 213.1. and 328± 478.7 and for the Ariadent alginate was 198.3 ± 215.5, 342.8± 227.3, 336.7± 280.9, and 281.9± 336.7 microns respectively. These differences were significant with respect to master model (P&lt;0.0005). &lt;/p&gt;&lt;p&gt;  The changes of measured dimensions within two groups were not significant statistically (P &lt;0.5). &lt;/p&gt;&lt;p&gt;  &lt;/p&gt;&lt;p&gt; &lt;strong&gt; Conclusion: &lt;/strong&gt;Both impression materials have significant dimensional changes which can not be used in fixed prosthodontics however they can be used in removable prosthodontics with adherence to the principles of standard guidelines. &lt;/p&gt;&lt;p&gt; &lt;strong&gt; &lt;/strong&gt;&lt;/p&gt;&lt;p&gt; &lt;strong&gt; Key word:&lt;/strong&gt;Dental Impression materials, Irreversible hydrocolloids, Dimensional changes  &lt;/p&gt;&lt;p&gt;  &lt;/p&gt;&lt;p&gt;  &lt;/p&gt;&lt;p&gt;  &lt;/p&gt;&lt;p&gt;  &lt;/p&gt;</abstract>
	<keyword_fa>ماده قالب گیری دندانی، هیدروکلوئید غیرقابل برگشت، تغییرات ابعادی</keyword_fa>
	<keyword>Dental Impression materials, Irreversible hydrocolloids, Dimensional changes</keyword>
	<start_page>168</start_page>
	<end_page>174</end_page>
	<web_url>http://jrds.ir/browse.php?a_code=A-10-149-3&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Parsa</first_name>
	<middle_name></middle_name>
	<last_name>Atashrazm</last_name>
	<suffix></suffix>
	<first_name_fa>پارسا</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>اتش رزم</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>10031947532846001732</code>
	<orcid>10031947532846001732</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>گروه پروتز متحرک</affiliation_fa>
	 </author>


	<author>
	<first_name>Naser</first_name>
	<middle_name></middle_name>
	<last_name>Valaee</last_name>
	<suffix></suffix>
	<first_name_fa>ناصر </first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>ولایی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>10031947532846001733</code>
	<orcid>10031947532846001733</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>دانشگاه ازاد اسلامی واحد دندانپزشکی تهران</affiliation_fa>
	 </author>


	<author>
	<first_name>Mahmood raza</first_name>
	<middle_name></middle_name>
	<last_name>Mobini</last_name>
	<suffix></suffix>
	<first_name_fa>محمود رضا  </first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>مبینی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>10031947532846001734</code>
	<orcid>10031947532846001734</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>دانشگاه ازاد اسلامی واحد دندانپزشکی تهران</affiliation_fa>
	 </author>


	<author>
	<first_name>leila</first_name>
	<middle_name></middle_name>
	<last_name>ZamaniAlavijeh</last_name>
	<suffix></suffix>
	<first_name_fa>لیلا</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>زمانی علویجه</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>10031947532846001735</code>
	<orcid>10031947532846001735</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>گروه پروتز متحرک</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
